Command
Transmitter System summary Specifications
OPERATING FREQUENCY RANGES:
370-450MHz
AMPLIFIER RF OUTPUT POWER:
1 kW Min at 1 dB
Compression (1,250Watt Typical)
RF OUTPUT POWER CONTROL:
23 dB Minimum in
0.1 dB Steps
RF OUTPUT PROTECTION:
Integral Output
Isolator protected No Oscillation at any Condition /Load
SMALL SIGNAL GAIN FLATNESS:
±1.5
dB Maximum Into 1.05:1 VSWR
INPUT AND OUTPUT IMPEDANCE:
50 Ohm Nominal
INPUT VSWR:
2.0:1 Maximum (Ref
50 Ohm)
HARMONIC SIGNAL LEVELS:
Integral Low Pass Filter -90dBc Maximum from 1100 – 2750 MHz
SPURIOUS SIGNAL LEVELS:
-55 dBc Maximum
RF OUTPUT CONNECTOR:
Type N Female
OUTPUT BLANKING ON/OFF RATIO:
40 dB Minimum
OUTPUT VSWR:
2:1 at Full power,
3:1 Reduced output Power to 250 W Reflected Maximum
RF OUTPUT TURN-ON-TIME:
<50 mSec after RF
power received
HARMONIC DISTORTION:
1% Maximum
MODULATION DISTORTION:
1% Maximum
LOCAL
CONTROL:
Via Color
Touchscreen LCD Display
REMOTE
CONTROL:
Via RS-232C at
38.4KB,N,8,1, Ethernet UDP/IP
COOLING:
Forced air via
integral Front Panel Intake and Rear Panel Exhaust Fans
OVER TEMPERATURE PROTECTION:
Thermostat Shut-Off
Indication at +85 Deg C Heatsink Temperature
TEMPERATURE RANGES:
Operating 0 to +50°C
ALTITUDE:
MSL to 70,000 Ft
CHASSIS DEPTH:
26.75”
Maximum
POWER SUPPLY:
Redundant N+1
Configuration
AC INPUT POWER:
180-264VAC, 47-63Hz
Three (3) Phase (One Phase Optional)
at 2.5KVA Maximum, built in N+1 Design
CONTROLS AND STATUS (ALL AVAILABLE BOTH IN
Local and Remote)
MANUAL/AUTOMATIC
FAILOVER EITHER TRANSMITTER
MULTIPLE REDUNANCY OPERATION MODES
CARRIER STNADBY/ONLINE
RF OUTPUT LEVEL CONTROL
FAULT ALARM (ALL FAULTS)
DEVIATION SELECTION
DEVIATION LEVEL MONITOR
VVA/ALC MODE
EXCITER
RF CARRIER
FREQUENCY
RF OUTPUT POWER
LOCAL / REMOTE ETHERNET AND RS232/422
CARRIER ON/OFF
TONE ON/OFF AND COMMAND ON/OFF
DEVIATION CONTROL/MONITOR
IRIG/HIGH ALPHA (SECURE TONE) /EFTS OPTIONS
COMMAND MODE OPTIONS
VERIFICATION RECEIVER
RF CARRIER
FREQUENCY
RF INPUT POWER
LOCAL / REMOTE ETHERNET AND RS232/422
CARRIER ON/OFF INDICATION
TONE DECODED AND COMMAND DECODED
DEVIATION MONITOR TOTAL AND INDIVIDUAL TONE
IRIG/HIGH ALPHA (SECURE TONE) /EFTS OPTIONS
COMMAND MODE OPTIONS
POWER SUPPLY
VOLTAGE AND CURRENT
FRONT PANEL METERS
INDIVIDUAL MODULE FRONT PANEL FAULT LED
REMOTE CPU MONITORED VOLTAGE/CURRENT/FAULTS
COOLING:
FORCED AIR ALL REAR
PANEL EXHAUST
WEIGHT:
1200 Lbs
Typical |